CORE-FILL 500™

Thermal Resistivity
ASTM C518-21
"R" Value of greater than 3.5/inch @ 75 degrees F mean
R - 4.91
per inch
Fire Safety
ASTM E-84
Flame spread not to exceed 25
Flame spread* 0
Smoke density 5
Corrosiveness
D.O.E. (e)(3)H.U.D. 6.2.8
Al, Cu, Steel - no Perforations; Galvanized steel - no pitting; Loss in mass not to exceed 0.2g
No perforations
No pitting
Less than 0.1g
Density
D.O.E. (e)(4)H.U.D. 6.1.4
Dry 0.7 to 0.9 lb/ft3
Wet 2.5 to 5.5 lb/ft3
0.8 lb/ft3
2.7 to 3.3 lb/ft3
Water Absorption
D.O.E. (e)(5)H.U.D. 6.2.9
Not to exceed 15%
No absorption in less than 1 hour
Floating test 3%Droplet test - 1 hr.15 min.
Acoustic Properties
ASTM E-90
STC Rating 50
STC Rating 53
OITC Rating 44
Shrinkage
D.O.E. (E)(11)H.U.D. 6.2.5
Not more than 4.0%
Less than 1%

*This numerical flame spread rating is not intended to reflect hazards presented by this or any other material under actual fire conditions